Vista de pagina 0
Five Year Warranty
User's Manual
Menu Driven Display
Humidify / Dehumidify Control
Fully Programmable
Brighter / Adjustable Backlight
Night Light Option
Auto Changeover
Automatic Daylight Saving Time
24 VAC with
Worry-Free Memory Storage
English, Spanish or
French Display Option
110-1175
9801
i
2
9825
i
2
DELUXE
PROGRAMMABLE
THERMOSTATS
110-1175 English 7/17/06 1:59 PM Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - User's Manual

Five Year Warranty User's ManualMenu Driven DisplayHumidify / Dehumidify ControlFully ProgrammableBrighter / Adjustable BacklightNight Light Opti

Pagina 2 - TABLE OF CONTENTS

OVERRIDE CURRENT SETTINGS page 2 of 2Setting a hold when the operating mode is Auto Changeover.When the selected mode is Auto Changeover, setting a ho

Pagina 3

OVERRIDE FAN OPERATIONNOTE: Choosing a fan mode (On, Auto or Intermittent) with the Fan Menu overrides the fan choices made when you use the MainMenu’

Pagina 4 - IMPORTANT SAFETY INFORMATION

PROGRAMMING THE THERMOSTAT page 1 of 2From the main screen, select Menu.From the Main Menu, select Schedule.Your schedule is based on the number of ev

Pagina 5

PROGRAMMING THE THERMOSTAT page 2 of 2From the main screen, select Menu, then Schedule, then Program. This will take you to the SelectProgram Days me

Pagina 6 - 3 Typical Main Screen Views

TIME & DAYNOTE: The main screen time/day/date line flashes until time and date are set.Select Time & Day from the Main Menu.With the Time &

Pagina 7 -

15HUMIDIFYChoose Humidify from the Main Menu.The three items available in this menu are explained below.Mode choices are:Off – Humidity level will not

Pagina 8 - CHOOSE HEATING/COOLING

16DEHUMIDIFYChoose Dehumidify from the Main Menu.The three items available in this menu are explained below.Mode choices are:Off – Humidity level will

Pagina 9 - Select Override Type

17COMFORT SETTINGS page 1 of 2NOTE: Every person has preferences about personal comfort. The following pages refer to a level of satisfaction with yo

Pagina 10 - Hold Temperature

COMFORT SETTINGS page 2 of 2Deadband is used only when the thermostat is set in the Auto Changeover mode. The deadband refersto a band or range betwee

Pagina 11 - OVERRIDE FAN OPERATION

CUSTOMIZE THE DISPLAY page 1 of 2User Preferences provides you with more ways to customize the displayed information and maintain optimal comfort.Fro

Pagina 12 - About EnergyStar

2TABLE OF CONTENTSImportant Safety Information ...

Pagina 13 - FAN SNSR

CUSTOMIZE THE DISPLAY page 2 of 2Air Quality – Sets service reminders for parts of the heating/cooling system that needperiodic attention.Based on th

Pagina 14 - TIME & DAY

SYSTEM SETTINGS page 1 of 5NOTE: Only the installing contractor should set System Settings.Choose System Settings from the Main Menu.The System Settin

Pagina 15 - Humidify Menu

SYSTEM SETTINGS page 2 of 51st Stage Cool equipment – Select Yes or No.2nd Stage Cool equipment can be selected for 9825i2 models only – Select Yes or

Pagina 16 - Select Dehumidify Mode

SYSTEM SETTINGS page 3 of 5Select Service Intervals to set service reminders for primary system components of theheating/cooling system that need peri

Pagina 17 - COMFORT SETTINGS page 1 of 2

SYSTEM SETTINGS page 4 of 5Auto Changeover – When this feature is selected, it allows thethermostat to switch automatically between heating and coolin

Pagina 18 - COMFORT SETTINGS page 2 of 2

SYSTEM SETTINGS page 5 of 5Security On/Off – This item provides security for the System Settings Menu only.To enable Security:Enter a four-digit PIN.

Pagina 19 - User Preference Menu

PREVENT THERMOSTAT ACCESSChoose User Security from the from the Main Menu when you want to prevent others from modifying thermostat operation.In effec

Pagina 20 - Replace Or Clean

TECHNICAL SUPPORTDo you have a question about your thermostat?Select Tech Support from the Main Menu to find technical support contact information.27T

Pagina 21 - SYSTEM SETTINGS page 1 of 5

FREQUENTLY ASKED QUESTIONS page 1 of 5Who should I call for help?Visit our web site at www.about-i-series.com.To talk with a Tech Support representati

Pagina 22 - SYSTEM SETTINGS page 2 of 5

FREQUENTLY ASKED QUESTIONS page 2 of 5What is deadband?The deadband refers to a range between the heating and cooling setpoints that controls how ofte

Pagina 23 - SYSTEM SETTINGS page 3 of 5

3Customize the DisplayFahrenheit or Celsius...

Pagina 24 - SYSTEM SETTINGS page 4 of 5

FREQUENTLY ASKED QUESTIONS page 3 of 5How many events can be programmed?This thermostat can be set for two, four, or six events per day.Select two eve

Pagina 25 - 0 0 0 0

FREQUENTLY ASKED QUESTIONS page 4 of 5Remote outdoor sensorThe remote outdoor sensor (Part No. 9025i) can be used to aid in the comfort of your home o

Pagina 26 - User Security Options

FREQUENTLY ASKED QUESTIONS page 5 of 5How do I reset the thermostat?To reset the thermostat, press the button and the LEFT button at the same time. H

Pagina 27 - Tech Support

FIVE YEAR LIMITED WARRANTYThe manufacturer warrants to the original contractor installer or to the original consumer user, each new Robertshaw thermo

Pagina 28

34NOTES110-1175 English 7/17/06 1:59 PM Page 34

Pagina 29

35NOTES110-1175 English 7/17/06 1:59 PM Page 35

Pagina 30

110-1175Controls Americas515 South Promenade AvenueCorona, CA 92879-1736United States of AmericaMade in U.S.A.Patents Pendingwww.about-i-series.com110

Pagina 31 - Night 10:00 PM Auto Rmt

4IMPORTANT SAFETY INFORMATIONWARNING:• Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off posit

Pagina 32

5KNOW YOUR THERMOSTAT'S CONTROLS AND DISPLAYS page 1 of 3NOTE: In many cases the installer made the initial setup of your thermostat. That was

Pagina 33 - FIVE YEAR LIMITED WARRANTY

6ModeMenu68.9Outside 42Set At 709:15AM Monday Jun 20A°F50%RHAnimated fan icon – rotatingblade shows the fan is on.KNOW YOUR THERMOSTAT'S CONTROL

Pagina 34

7KNOW YOUR THERMOSTAT'S CONTROLS AND DISPLAYS page 3 of 33 Typical Menu ViewsEquipment Setup MenuBackSelect1st Stg Cool Yes2nd Stg Cool NoShor

Pagina 35

CHOOSE HEATING/COOLINGTo choose a mode (of operation), select Mode.There are five possible operating modes:Off – The heating/cooling systems are turne

Pagina 36

OVERRIDE CURRENT SETTINGS page 1 of 2NOTES: These directions are for both Heating and Cooling.Hold does not appear in the Main Menu if Off is the sele