Models
9801
i
,
9815
i
and
9820
i
Quick Start Installation Manual
111-321D
Installation DOs and DON’Ts
DO
Shut off all power to system before installing.
Read entire manual before installing.
Make sure that all wiring conforms to
national and local codes.
DO NOT
Install on voltages greater than 30 VAC.
Short jumper across terminals on the gas
valve or at the system control.
Connect ground to any terminal in
this unit.
Install on outside walls or in direct sunlight.
Select location for installation.
1
Open the case with a screwdriver. Place
in slot and gently pry forward at all four
locations.
2
Mark mounting hole locations on wall.
3
Drill
3
/
16
” holes at marked locations on
wall. Insert plastic anchors into holes.
4
Align unit base over plastic anchors
embedded in wall and secure with the
screws provided.
5
Connect wiring between unit and
furnace. For Model 9801i (1H/1C
furnace applications).
6
Cut
out
opening
a
b
1/4"
1-1/2"
1"
1
2
3
4
Mark mounting hole
locations on wall using
unit base as template.
Drill
3
/
16
holes
a
b
Press anchors into holes until flush.
Y1
R
C
E/W1
H O B G
Thermostat
C - 24VAC Common
R - 24VAC
Y1 - 1st stage cooling
E/W1 - 1st stage heating
O - Not used
B - Not used
G - Fan
H - Humidification
TERMINAL DESIGNATIONS
C
C
H
R
Y
W
G
B
O
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
9801i
Humidifier
Equipment Wiring
Terminals
Please refer to furnace
installation manual for
proper terminations
Remove 1/4” of insulation
from end of each wire
DELUXE
PROGRAMMABLE
THERMOSTATS
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - 1-1/2"

Models 9801i, 9815iand 9820iQuick Start Installation Manual111-321DInstallation DOs and DON’TsDO• Shut off all power to system before installing.• Rea

Pagina 2 - Recycling Thermostat

NOTE: For 9801i single stage heatpump applications, place a jumperbetween the E/W1 and Y1 terminals.7Connect wiring between unit and furnace. For Mode

Modelos relacionados 9815I | 9801I |

Comentarios a estos manuales

Sin comentarios